Specs at a glance
-
Process temperature
0 to 60 °C (32 to 140 °F)
Field of application
The Flexdip CYA112 is a modular assembly for sensor immersion in open basins, channels, or tanks. It allows nearly any kind of sensor mounting – chain, fixed, or free-swinging – and features a quick fastener for rapid and safe installation of Memosens or fixed-cable sensors. The assembly provides you with outstanding flexibility and enables you to optimally configure your measurement at low costs.
Flexdip CYA112 is a modular assembly for all measurements in open basins, channels and tanks in:
Wastewater treatment plants
Water works
Utilities of all industries
It forms a perfect team with the Flexdip CYH112 holder for simple sensor isolation.
The Flexdip team is suitable for all parameters, such as:
pH/ORP
Conductivity
Oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
Benefits
The modular system allows an optimum configuration for every measuring place
Fast installation and exchange of Memosens sensors with contactless plug-in head
Twist-free installation of fixed-cable sensors
Easy to install and to maintain
Robust design: Suitable for process pressures up to 6 bar (87 psi)
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Flexdip CYA112
Immersion assembly for water and wastewater
EN Select other language 13/12/201929/05/201201/05/2009Language:
English
Version:
13/12/2019
File size:
708.9 KB
File name:
TI00432CEN_1419.pdf
-
-
-
Operating Instruction (BA)
Flexdip CYA112
Wastewater assembly
EN Select other language 13/12/201921/08/201301/05/2009Language:
English
Version:
13/12/2019
File size:
954.8 KB
File name:
BA00432CEN_1419.pdf
-
-
-
Fields of Activities (FA)
Sensors, transmitters, compact devices and assemblies
Experts in Liquid Analysis
Language:
English
Version:
24/09/2024
File size:
4.2 MB
File name:
FA00007CEN_Analyse_21.24_LowRes.pdf
-
-
-
Fields of Activities (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
Kompetenz in der Flüssigkeitsanalyse
Language:
German
Version:
24/09/2024
File size:
4.1 MB
File name:
FA00007CDE_Analyse_21.24_LowRes.pdf
-
-
-
Competence Brochure (CP)
Leitfähigkeitsmessung in Industrieprozessen
Auswahl- und Engineeringhilfe für verschiedene Industrien und
AnwendungenLanguage:
German
Version:
27/04/2023
File size:
2.4 MB
File name:
CP01313CDE_0223_LF_Auswahlhilfe_web.pdf
-
-
-
Competence Brochure (CP)
pH measurement in industrial processes
Selection and engineering guide for different industries and
applicationsLanguage:
English
Version:
02/12/2021
File size:
3.2 MB
File name:
CP00010CEN_1621_pH selection guide_2021.pdf
-
-
-
Competence Brochure (CP)
産業プロセスにおける導電率の測定
さまざまな産業およびアプリケーション向けの選択およびエンジニアリングガイド
Language:
Japanese
Version:
12/01/2024
File size:
3.5 MB
File name:
CP01313CJA_0223_1024_Conductivity_sensor_selection_guide.pdf
-
-
-
Competence Brochure (CP)
産業プロセスにおけるpH測定
さまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Language:
Japanese
Version:
08/02/2024
File size:
2.6 MB
File name:
CP00010CJA_1315_1024_pH_selection_guide.pdf
-
-
-
Competence Brochure (CP)
Conductivity measurement in industrial processes
Selection and engineering guide for different industries and
applicationsLanguage:
English
Version:
27/04/2023
File size:
2.5 MB
File name:
CP01313CEN_0223_cond_selection_guide_web.pdf
-
-
-
Competence Brochure (CP)
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenLanguage:
German
Version:
01/12/2021
File size:
3.3 MB
File name:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
-
-
-
Case Study (CS)
Improved thickener operation at Minera Valle Central
Improved thickener operation at Minera Valle Central
Online interface and turbidity measurement with CUS71D and CUS52DLanguage:
English
Version:
30/05/2022
File size:
720.2 KB
File name:
CS01741C40EN01.22_Improved thickener operation at Minera Valle Central.pdf
-
-
-
Case Study (CS)
Real time monitoring of water quality in aquaculture systems
CSIRO utilises Netilion Water Networks Insight (NWNI) to gain complete
visibility of process changes in their aquaculture researchfacility.
The turnkey cloud-based solution allows for real-time monitoring of
water quality parameters DO, pH, temperature and salinity.Language:
English
Version:
15/07/2021
File size:
330.4 KB
File name:
CS01706S36EN_01.21_Real time monitoring of water quality in aquaculture systems - Case study.pdf
-
-
-
Case Study (CS)
Echtzeitüberwachung der Wasserqualität in Aquakulturanlagen
Vollständige Transparenz bei Prozessänderungen mit einer
Cloud-basierten KomplettlösungLanguage:
German
Version:
15/07/2021
File size:
677.9 KB
File name:
CS01706S_0121_Echtzeitueberwachung der Wasserqualitaet in Aquakulturanlagen.pdf
-
-
-
Accessories
71131024 (European Union)
Tangit PVC-U Klebstoff
Language:
English
Version:
05/09/2024
File size:
308 KB
File name:
MSDS_71131024_(EU).pdf
-
-
-
Accessories
71131024 (United Kingdom)
Tangit PVC-U Klebstoff
Language:
English
Version:
05/09/2024
File size:
289.3 KB
File name:
MSDS_71131024_(GB).pdf
-
-
-
AI (Application note)
Badespaß in sicherem Gewässer
Überwachung der Wasserqualität mit dem CUS52D
Language:
German
Version:
29/09/2021
File size:
623.5 KB
File name:
AI01252C_Badespass in sicherem Gewaesser.pdf
-
-
-
Tender Text
Armatur, Messstelle Leitfähigkeit, CYA 112, Sensoranschluss G 3/4
Eintaucharmatur zum Festeinbau oder zur Montage mittels einer
Pendelhalterung, zur Aufnahme eines Leitfähigkeitssensors mit gerademS
ensoranschluss und Anschlussgewinde G 3/4 (z.B. Endress+Hauser
CLS 50)Language:
German
Version:
06/12/2012
File size:
28 KB
File name:
TTCYA122_G3-4DE.doc
-
-
-
Tender Text
Armatur, Messstelle Sauerstoff, CYA 112, Sensoranschluss G1
Eintaucharmatur zum Festeinbau oder zur Montage mittels einer
Pendelhalterung, zur Aufnahme eines Sauerstoffsensors mit geradem
Sens
oranschluss und Anschlussgewinde G 1 (z.B. Endress+Hauser COS 31;
COS 41; COS 61D)Language:
German
Version:
06/12/2012
File size:
36.5 KB
File name:
TTCYA112_G1_O2DE.doc
-
-
-
Tender Text
Armatur, Messstelle Schlammspiegel, CYA 112, Sensoranschluss G1"
Eintaucharmatur zum Festeinbau oder zur Montage mittels einer starren
Halterung, zur
Aufnahme eines Ultraschallsensors zur Schlammspiegelmessung mit geradem
Sensoranschluss und Anschlussgewinde G 1 (z.B. Endress+Hauser CUS 70)Language:
German
Version:
23/06/2016
File size:
25.5 KB
File name:
TTCYA112_G1_SchlammspiegelDE.doc
-
-
-
Tender Text
Armatur, Messstelle pH, CYA 112, Sensoranschluss Pg 13.5
Eintaucharmatur zum Festeinbau oder zur Montage mittels einer
Pendelhalterung, zur Aufnahme einer pH-Elektrode mit geradem Sensorans
chluss und Anschlussgewinde Pg 13,5 (z.B. Endress+Hauser CPSx1D; CPSx1)Language:
German
Version:
09/03/2010
File size:
30 KB
File name:
TTCYA112_PG13.5DE.doc
-